Description
| Energy label | A+++ |
| Heating power | 10 kW |
| EER/COP | 4.80/5.00 |
| WIFI | yes |
| OUTDOOR UNIT | HOP10WODU |
| Heating (A7/W35) | 10 kW |
| Cooling (A35/W18) | 10 kW |
| EER | 4.80 W/W |
| COP | 5.00 W/W |
| Water temperature:
SCOP 35°C/55°C SEER 7°C/18°C |
5,2/3,47 5,98/8,78 |
| Power supply
Rated power Rated current Automatic switch Power cable |
220-240 V / 50Hz 1 phase
3600W 16,0 A C20 ~1 3 x 2,5 mm2 |
| Refrigerant type
Refrigerant quantity in the device Refrigerant replenishment |
R32 (675)
1.65 kg 38 g/m |
| Between the indoor and outdoor blocks track length, Height (min.-max.) | 3-30 m(length), 20 m (height) |
| Compressor
Fan |
DC two rotor inverter
DC electric motor |
| Sound level
Sound pressure (at a distance of 1m) |
60 dB(A)
49 dB(A) |
| Dimensions
Net / Gross weight |
1118×865×523 mm
78,5 / 92 kg |
| Outdoor operating temperature:
Heating Cooling Hot water preparation |
-25 ~ +35°C -5 ~ +43°C -25 ~ +43°C |
| INDOOR UNIT WITH BUILT-IN HOT WATER TANK | HOP100/190IDU |
| WATER TANK:
Capacity Material Max water temperature Isolation |
190 L Stainless Steel, SUS 316L 70 °C Polyurethane |
| Built-in electric heater | 3kW |
| Power supply
Rated power Rated current Power cable |
220-240/1/50 V/Ph/Hz
3095W 13,5A 3×2,5 mm2 |
| Circulation pump:
Type Maximum lifting height Power |
DC, electronic 9 m 5~90 W |
| Heat exchanger
Expansion tank |
Plate, soldered
8 L |
| Supply water temperature:
Heating Cooling Hot water preparation |
+12 ~ +65°C +5 ~ +30°C +12 ~ +60°C |
| Ambient temperature | +5 ~ +35°C |
| Water pressure in the heating/cooling system | 1 ~ 2,5 bar |
| Water pressure in the hot water system (cold water) | 1,5 ~ 3 bar |
| Dimension | 600x1683x600 mm |
| Net/gross weight | 139 / 154 kg |
| Delivery cost | 60 Eur |